EATON Dual AC Level 2 Charging Station Wall Mount
SWS# 3020 |
Eaton’s Dual AC Level 2 charging station is Electric Vehicle Supply
Equipment (EVSE) and is compatible with the Society of Automotive
Engineers J1772™ standard for charging plug-in hybrid and all-electric vehicles.
The Dual Level 2 EV Charging Station has several safety features:
• Protects Users with interlocked power – the cable and pins have
no power on them until the connector is safely plugged into a
vehicle.
• Protects Users from temporary faults – and automatically resets*
so no User interaction is needed.
• Instructs the vehicle on how much current to draw – keeps the
upstream circuit protection from ‘nuisance tripping.’
• Allows integration into authorization and management systems keeping only authorized personnel able to use units and power usage levels to predefined levels.
Electrical and Mechanical Specifications | 30 amps | 48 amps | 70 amps |
Incoming Voltage |
208/240 VAC120 VAC*Line 1, Line 2, Earth Ground |
||
Input Frequency |
50/60Hz |
||
Upstream Breaker Size |
40 A |
60 A |
90 A |
Output Voltage |
Same as Incoming |
||
Output Frequency |
Same as Incoming |
||
Output Amperage - Max Continuous |
30 A |
48 A |
70 A |
Interlocked Power Output |
Yes |
||
Overcurrent Rating |
Output Amperage + 5% |
||
Ground Fault Interruption |
20mA(UL2231-1/UL2231-2 Personnel Protection) |
||
Automatic Reset after Nuisance TripFeature |
DIP switch selectable Enable/Disable(default Enabled) |
||
Randomized Restart On PowerFailure (delay before chargingresumes after a power failure) |
Yes(randomized across a time range to staggerpower up across deployments) |
||
Mechanical Operations |
10,000 cycles (EV Connector, replaceable)100,000 cycles (Contactor, replaceable) |
||
Incoming Field Electrical ServiceTerminal Block Torque in in-lb (Nm) |
22.1 – 26.6 (2.5 – 3) |
||
Incoming Modbus ConnectionsTerminal Block Torque in in-lb (Nm) |
4.4 – 5.3 (.5 - .6) |
Physical and Environmental Specifications. |
Description | Wall-mount | Pedestal |
Dimensions - H x W x D | 30.13 x 15.37 x 11.23 in (765.3 x 390.4 x 285.2 m) |
50.03 x 16.41 x 8.35 in (1270.8 x 416.8 x 212.1 m) |
Status Indicators | 6 LEDs: ‘Power’, ‘Charging’, ‘Complete’, ‘Remotely Controlled’, ‘Temporary Fault’, and ‘Service’ |
Push Buttons | 2 Buttons: ‘Override’ and ‘Reset’ |
Type Rating | 3R |
Temperature – Operating* | -30 to 50 degrees Celsius |
Temperature – Storage | -40 to 70 degrees Celsius |
Humidity | 90% RH, non-condensing |
* 48A and 70A are 40°C maximum temperatures.