Models: SR961s / SR962s
Intelligent and Efficient Solar Water Heater Control
The SR961s/SR962s solar water heater working station utilizes an efficient design and intelligent controller for high-performance control of your solar water heater system. The station comes complete with a pressure gauge, charging/draining ports that utilize a check valve to ensure one-way flow during charging/operation, a connection for an expansion tank, efficient and reliable wilo pump (made in Germany), insulation cover, and a sleek metal enclosure.
Enjoy years of operation with efficient control of the circulation pump. This unit consumes less than 4 watts during operation. (The national average cost to operate this unit is no more than 30 cents a month!) Digital speed control of the pump allows for the most efficient use of your pump's electrical power. When high pumping speeds are needed, it can circulate quickly to obtain heat. When heating is average, the pump levels out to a nice slow speed for efficient and even operation.
The SR962s model has a two pipe system. The 2nd pipe is for the return from the solar collector, which has an additional sensor for detecting the temperature of the fluid returning from the collector.
SR961s/SR962s Technical Data | |
Height |
420mm (16.5") |
Width |
280mm (11") |
Thickness |
140mm (5.5") |
Distance between flow/return |
160mm (6.2") |
Max Pressure |
10 Bar (145 psi) |
Max Temperature |
130°C (266°F) |
Pipe Connections |
2 x G1/2 (SR961s)4 x G1/2 (SR962s) |
Safety Valve Pressure |
6 Bar (87psi) |
Connector for Expansion Tank |
G1/2, male |
Type of Pump |
Wilo RS 15/16 |
Max Flow Rate |
2.5 t/h (11 gpm) |
*Max Pump Head |
5.5m (18 ft) |
Max Operation Pressure |
10 Bar (145 psi) |
Power Supply |
110v AC 50/60 Hz or 220v AC 50/60Hz |
Ball Valves |
G1/2 |
Flow Meter |
0.1~20 L/min |
Flushing Connections |
G1/2 |
Thermal Insulation |
EPS/EPP |
Front Cover Material |
st14 |
Pipe Sensor Types |
NTC10 K, B=3950 |
*Much more head can be obtained in a closed loop, especially with fluid pressure built into the system
Manufacturer's Specifications